About: Inertial response     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : dbo:Disease, within Data Space : dbpedia.demo.openlinksw.com associated with source document(s)
QRcode icon
http://dbpedia.demo.openlinksw.com/describe/?url=http%3A%2F%2Fdbpedia.org%2Fresource%2FInertial_response&invfp=IFP_OFF&sas=SAME_AS_OFF&graph=http%3A%2F%2Fdbpedia.org&graph=http%3A%2F%2Fdbpedia.org

Inertial response is a property of large synchronous generators, which contain large synchronous rotating masses, and which acts to overcome any immediate imbalance between power supply and demand for electric power systems, typically the electrical grid. Due to the ever existing power imbalance between mechanical power supply and electric power demand the rotational frequency of the rotating masses in all synchronous generators in the grid either speed up (excess power supply) or slow down (excess power demand). This enables the grid operator to rebalance the system in order to stop the speed change, resulting in a relatively small variation in AC frequency ideally within the allowable frequency range of that system. i.e. A 50 Hz system may allow a ±0.5 Hz deviation in the frequency of th

AttributesValues
rdf:type
rdfs:label
  • Inertial response (en)
  • Svängmassa (sv)
rdfs:comment
  • Inertial response is a property of large synchronous generators, which contain large synchronous rotating masses, and which acts to overcome any immediate imbalance between power supply and demand for electric power systems, typically the electrical grid. Due to the ever existing power imbalance between mechanical power supply and electric power demand the rotational frequency of the rotating masses in all synchronous generators in the grid either speed up (excess power supply) or slow down (excess power demand). This enables the grid operator to rebalance the system in order to stop the speed change, resulting in a relatively small variation in AC frequency ideally within the allowable frequency range of that system. i.e. A 50 Hz system may allow a ±0.5 Hz deviation in the frequency of th (en)
  • Svängmassa är ett viktigt sätt att åstadkomma en tröghet i kraftnätet som gör att nätfrekvensen och spänning inte förändras alltför snabbt vid en obalans mellan tillförd och använd energi. Ibland används också det snarlika begreppet rotationsenergi för att beskriva samma fenomen. Svängmassa bidrar till en tröghet i systemet som begränsar plötsliga förändringar i nätfrekvens. Ursprungligen var en stor svängmassa i princip det enda sättet att en stabil spänning och frekvens i elsystemet. Efterhand har det det utvecklats även andra metoder med hjälp av olika typer av kraftelektronik kopplat till någon form av energilager som mycket snabbt (millisekunder) kan absorbera eller avge en stor effekt. Svenska kraftnät använder gärna begreppet eftersom det innefattar flera olika sätt att åstadkomma (sv)
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
has abstract
  • Inertial response is a property of large synchronous generators, which contain large synchronous rotating masses, and which acts to overcome any immediate imbalance between power supply and demand for electric power systems, typically the electrical grid. Due to the ever existing power imbalance between mechanical power supply and electric power demand the rotational frequency of the rotating masses in all synchronous generators in the grid either speed up (excess power supply) or slow down (excess power demand). This enables the grid operator to rebalance the system in order to stop the speed change, resulting in a relatively small variation in AC frequency ideally within the allowable frequency range of that system. i.e. A 50 Hz system may allow a ±0.5 Hz deviation in the frequency of the AC voltage The grid frequency is the combined result of the detailed motions of all individual synchronous rotors in the grid, which are modeled by a general equation of motion called the swing equation. Inertia is often normalized to the "size" (electrical power) of the generator and thus can be described in the units of time (seconds). The faster spinning generators might store more kinetic energy (proportional to square of the rotational frequency), but are typically lighter and thus decelerate faster, causing more power to be injected early in the response ("front-loading") when compared to the slower and heavier machines; this is not necessarily better due to interaction between parts of the grid that can cause "bouncing" and instability. (en)
  • Svängmassa är ett viktigt sätt att åstadkomma en tröghet i kraftnätet som gör att nätfrekvensen och spänning inte förändras alltför snabbt vid en obalans mellan tillförd och använd energi. Ibland används också det snarlika begreppet rotationsenergi för att beskriva samma fenomen. Svängmassa bidrar till en tröghet i systemet som begränsar plötsliga förändringar i nätfrekvens. Ursprungligen var en stor svängmassa i princip det enda sättet att en stabil spänning och frekvens i elsystemet. Efterhand har det det utvecklats även andra metoder med hjälp av olika typer av kraftelektronik kopplat till någon form av energilager som mycket snabbt (millisekunder) kan absorbera eller avge en stor effekt. Svenska kraftnät använder gärna begreppet eftersom det innefattar flera olika sätt att åstadkomma önskad tröghet i elkraftsystemet. Fysiskt utgörs svängmassan av tröghetsmomentet i de roterande massorna hos de tillkopplade kraftverkens synkrona generatorer och turbiner. De har en mekanisk tröghet mot förändringar i rotationshastighet och kan därmed inte accelereras eller bromsas in hur snabbt som helst. Eftersom generatorerna är synkront kopplade till nätet översätts det till en tröghet i själva nätfrekvensen. I kraftnätet måste det i varje givet ögonblick råda balans mellan producerad och förbrukad energi. Svängmassan hjälper att upprätthålla balansen genom att fungera som en kortsiktig energibuffert i form av svänghjul. När rotationsenergi används upp roterar massorna långsammare och nätfrekvensen sjunker. Ju större massa, desto mer energi lagras och desto mindre påverkas frekvensen av en effektobalans. Nedstängning av kärnkraftverk och kraftverk baserade fossil energi riskerar att leda till minskad svängmassa och öka kraftnätets sårbarhet. Det har väckt frågan om nya investeringar måste göras för att öka trögheten i det svenska kraftsystemet i Sydsverige. (sv)
gold:hypernym
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 59 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software