In electrical engineering, the power factor of an AC power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing work. Apparent power is the product of RMS current and voltage. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power may be greater than the real power, so more current flows in the circuit than would be required to transfer real power alone. A power factor magnitude of less than one indicates the voltage and current are not in phase, reducing the average produ

AttributesValues
rdf:type
rdfs:label
  • معامل القدرة (ar)
  • Factor de potència (ca)
  • Účiník (cs)
  • Leistungsfaktor (de)
  • Faktoro de povumo (eo)
  • Factor de potencia (es)
  • Facteur de puissance (fr)
  • Faktor daya listrik (in)
  • Fattore di potenza (it)
  • 力率 (ja)
  • 역률 (ko)
  • Arbeidsfactor (nl)
  • Power factor (en)
  • Fator de potência (pt)
  • Współczynnik mocy (pl)
  • Коэффициент мощности (ru)
  • Коефіцієнт потужності (uk)
  • 功率因数 (zh)
rdfs:comment
  • En enginyeria elèctrica, el factor de potència d'un sistema de potència elèctric de corrent altern es defineix com la ràtio entre la potència real i la potència aparent. És un paràmetre sense dimensions i el seu interval va de -1 A +1. El seu símbol és FP o també cos φ. Les càrregues resistives pures tenen un FP=1, en canvi les càrregues inductives pures (inductives o capacitives) tenen un FP=0. (ca)
  • La faktoro de povumo estas karakteriza grando de elektra ricevilo. Ĝi egalas al la kvociento de la aktiva povumo transdonita al la ricevilo per la ŝajna povumo. La valoro de estas ĉiam inter 0 kaj 1. Se la kurento kaj la tensio estas sinusaj funkcioj de la tempo, la faktoro de povumo egalas al la kosinuso de la inter la kurento kaj la tensio. (eo)
  • Als Leistungsfaktor (auch Wirkleistungsfaktor) wird in der elektrischen Wechselstromtechnik das Verhältnis vom Betrag der Wirkleistung zur Scheinleistung bezeichnet. Das Verhältnis wird in folgender Formel ausgedrückt: Der Leistungsfaktor kann zwischen 0 und 1 liegen: (de)
  • Se define factor de potencia, f.d.p., de un circuito de corriente alterna, potencia activa, P, y la potencia aparente, S.​Da una medida de la capacidad de una carga de absorber potencia activa. Por esta razón, f.d.p = 1 en cargas puramente resistivas. (es)
  • Faktor daya listrik adalah nilai perbandingan antara dan . Rentang nilainya berkisar antara nol hingga satu. Faktor daya listrik dinyatakan dengan nilai cos φ. Pengamatan faktor daya listrik didasarkan pada jumlah arus listrik keseluruhan dalam suatu rangkaian listrik dan perbandingannya dengan jumlah arus yang terpakai. Pengambaran faktor daya dilakukan melalui sudut kosinus antara arus listrik dan tegangan listrik yang bekerja pada suatu . Faktor daya berguna untuk mengetahui tingkat efisiensi energi pada suatu beban listrik melalui nilai daya yang tidak terpakai dan terbuang sia-sia selama beban bekerja. (in)
  • 力率(りきりつ、Power factor)は、交流電力の効率に関して定義された値であり、皮相電力に対する有効電力の割合である。料金計算などの電力の管理では、パーセントで表される。 (ja)
  • O fator de potência (FP) é uma relação entre potência ativa e potência reativa por consequência energia ativa e reativa. Ele pode ser usado para indicar se a proporção entre potência reativa e ativa está adequada. O fator de potência de um sistema elétrico qualquer, que está operando em corrente alternada (CA), é definido pela razão da potência real ou potência ativa pela potência total ou potência aparente. Um FP alto indica uma boa eficiência quanto ao uso de energia, significa dizer que grande parte da energia drenada é transformada em trabalho, inversamente a isso um fator de potência baixo indica que você não está aproveitando plenamente a energia drenada (entende-se por "energia drenada" a energia que você compra da concessionaria). (pt)
  • Коефіціє́нт поту́жності — безрозмірна фізична величина, що означує споживача змінного електричного струму з точки зору наявності в навантаженні реактивної складової. Коефіцієнт потужності показує, наскільки зсувається по фазі змінний струм, що протікає крізь навантаження, щодо прикладеної до нього напруги. Чисельно коефіцієнт потужності дорівнює косинусу цього фазового зсуву. (uk)
  • Коэффицие́нт мо́щности — безразмерная физическая величина, характеризующая потребителя переменного электрического тока с точки зрения наличия в нагрузке реактивной составляющей и мощности искажения (собирательное название — неактивная мощность). Следует отличать понятие «коэффициент мощности» от понятия «косинус фи», который равен косинусу сдвига фазы переменного тока, протекающего через нагрузку, относительно приложенного к ней напряжения. Второе понятие используют в случае синусоидальных тока и напряжения, и только в этом случае оба понятия эквивалентны. (ru)
  • معامل القدرة (Power Factor) هو النسبة بين إلى ، وهو مساوِ لجيب تمام زاوية الطور (cos_phi) - والتي هي فرق زاويتي الجهد والتيار. لذا فهو قيمة عددية ليس لها وحدة قياس تتراوح من الصفر إلى الواحد، في محطات القدرة يحبذ ويتم السعي إلى أن يكون معامل القدرة أكبر ما يمكن حيث أنه بزيادة درجة معامل القدرة يزداد مقدارالقدرة الفعالة وتنخفض القيمة أو وتتراوح قيم معاملات القدرة في محطات القدرة التي تعتمد نظام التيار المتردد الأحمال الكهربائية تقع في إحدى التصنيفات التالية: * مقاوِم Resistive * حثي Inductive * سعوي Capacitive (ar)
  • Účiník je kosinus vzájemného fázového posuvu mezi proudem a napětím elektrického obvodu s harmonickými průběhy střídavých proudů a napětí či periodickými průběhy o jednotlivých harmonických složkách proudů a napětí. Účiník je poměrem činného a zdánlivého elektrického výkonu v obvodu střídavého proudu a napětí, vyjadřuje, jak velkou část zdánlivého výkonu přeměňuje obvod na činný výkon, tj. na součet užitečného výkonu a ztrát. Značka: Jednotka SI: - (cs)
  • In electrical engineering, the power factor of an AC power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing work. Apparent power is the product of RMS current and voltage. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power may be greater than the real power, so more current flows in the circuit than would be required to transfer real power alone. A power factor magnitude of less than one indicates the voltage and current are not in phase, reducing the average produ (en)
  • In ingegneria elettrica, il fattore di potenza di un sistema elettrico a corrente alternata è il rapporto fra il modulo del vettore potenza attiva che alimenta un carico elettrico e il modulo del vettore potenza apparente che fluisce nel circuito. In un sistema con carichi lineari coincide con il coseno dell'angolo di sfasamento compreso tra i vettori tensione e corrente. È un numero adimensionale nell'intervallo chiuso tra -1 e 1. In quasi tutti i circuiti reali, la corrente è in ritardo rispetto alla tensione e la potenza apparente risulta quasi sempre maggiore della potenza attiva. (it)
  • Le facteur de puissance est une caractéristique d'un récepteur électrique qui rend compte de son efficacité pour consommer de la puissance lorsqu'il est traversé par un courant. Pour un dipôle électrique alimenté en régime de courant variable au cours du temps (sinusoïdal ou non), il est égal à la puissance active P consommée par ce dipôle, divisée par le produit des valeurs efficaces du courant I et de la tension U (puissance apparente S). Il est toujours compris entre 0 et 1. (fr)
  • 전기에는 직류와 교류가 존재하는데, 역률(영어: power factor)은 교류와 관계된다. 왜냐하면, 직류에서는 전압과 전류의 곱으로 전력이 되는데, 그 공식은 아래와 같이 나타낼 수 있다. P = 전력, V = 전압, I = 전류 직류에서는 위상이라는 개념이 없다. 하지만, 교류에서는 위상이 존재하며, 교류회로에서 역률은 (Active Power [단위 : W])과 (Apparent Power [단위 : VA])의 비를 말하는데, 이를 간단히 풀어서 해석하면, “전기설비에 걸리는 전압과 전류가 얼마나 효율적으로 일을 잘 하고 있는가?”로 나타내는 지표로도 활용된다. 역률은 유효전력을 피상전력(외관상의 전력)으로 나눈값이며, 교류 회로에서 전류와 전압의 위상차를 코사인 값(cosθ)으로 나타낸다. 직류에서는 전압과 전류만 곱하면 그것이 전력이었으나, 교류는 전압과 전류의 실효값을 곱한 피상전력이라는 것에 역률을 곱하여야 비로소 전력이 된다. 왜냐하면 직류처럼 일정한 흐름이 아닌, 정현파의 형태를 그리며 계속 지속적으로 변하기 때문이다. 즉, 직류처럼 일정한 값이 아닌, 계속 지속적으로 변하는 값이기 때문에 위상이 반드시 일치하지는 않는 것이다. (단, 위상각) (ko)
  • De arbeidsfactor of vermogensfactor is de verhouding tussen het werkelijke vermogen en het schijnbare vermogen in een wisselspanningsinstallatie. Het schijnbare vermogen is het product van de effectieve waarde van de elektrische spanning en van de elektrische stroomsterkte, en wordt uitgedrukt in de eenheid voltampère: Het werkelijke vermogen is de per tijdseenheid overgebrachte hoeveelheid energie, het deel van het vermogen dat daadwerkelijk wordt omgezet in warmte en arbeid. Het wordt uitgedrukt in watt (W): (nl)
  • Współczynnik mocy, – stosunek mocy czynnej do mocy pozornej, czyli stosunek mocy użytecznej do iloczynu napięcia i prądu. Powszechnie dziś stosowane w elektrotechnice pojęcie współczynnika mocy wprowadził pod koniec XIX wieku uczony polskiego pochodzenia Michał Doliwo-Dobrowolski pracujący wówczas w niemieckim koncernie AEG. W obwodach zasilanych napięciem sinusoidalnie zmiennym, a powodujących powstawanie prądu o przebiegach okresowych niesinusoidalnych, rozpatruje się bardzo często dwie składowe współczynnika mocy: Całkowity współczynnik mocy wynosi wtedy: gdzie: (pl)
  • 功率因数(英語:power factor,縮寫:PF)又称功率因子,是交流電力系統中特有的物理量,是一負載所消耗的与其视在功率的比值,是0到1之間的無因次量。 有功功率代表一電路在特定時間作功的能力,视在功率是電壓和電流有效值的乘積。純電阻負載的视在功率等於有功功率,其功率因數為1。若負載是由電感、電容及電阻組成的線性負載,能量可能會在負載端及電源端往復流動,使得有功功率下降。若負載中有電感、電容及電阻以外的元件(非線性負載),會使得輸入電流的波形扭曲,也會使视在功率大於有功功率,這二種情形對應的功率因数會小於1。功率因数在一定程度上反映了发电机容量得以利用的比例,是合理用电的重要指标。 電力系統中,若一負載的功率因數較低,負載要產生相同功率輸出時所需要的電流就會提高。當電流提高時,電路系統的能量損失就會增加,而且電線及相關電力設備的容量也隨之增加。電力公司為了反映較大容量設備及浪費能量的成本,一般會對功率因數較低的工商業用戶以較高的電費費率來計算電費。 提高負載功率因數,使其接近1的技術稱為功率因數修正。低功率因數的線性負載(如感應馬達)可以藉由電感或電容組成的被動元件網路來提昇功因。非線性負載(如二極體)會使得輸入電流的波形扭曲,此情形可以由主動或被動的功率因數修正來抵消電流扭曲的影響,並且改善功因。功率因數修正設備可以位在中央變電站、分佈在電力系統中,或是放在耗能設備的內部。 (zh)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/Active_pfc_PSU_packaging.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/Blindleistungskompensation.svg
  • http://commons.wikimedia.org/wiki/Special:FilePath/Condensatorenbatterij.jpg
  • http://commons.wikimedia.org/wiki/Special:FilePath/Condensor_bank_150kV_-_75MVAR.jpg
  • http://commons.wikimedia.org/wiki/Special:FilePath/Lagging-Leading.jpg
  • http://commons.wikimedia.org/wiki/Special:FilePath/Power_Factor_General_Case.svg
  • http://commons.wikimedia.org/wiki/Special:FilePath/Power_factor_0.7.svg
  • http://commons.wikimedia.org/wiki/Special:FilePath/Power_factor_0.svg
  • http://commons.wikimedia.org/wiki/Special:FilePath/Power_factor_75_2.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/Power_triangle_diagram.jpg
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 50 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software