About: Seismic vibration control     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : owl:Thing, within Data Space : dbpedia.demo.openlinksw.com associated with source document(s)
QRcode icon
http://dbpedia.demo.openlinksw.com/describe/?url=http%3A%2F%2Fdbpedia.org%2Fresource%2FSeismic_vibration_control&invfp=IFP_OFF&sas=SAME_AS_OFF&graph=http%3A%2F%2Fdbpedia.org&graph=http%3A%2F%2Fdbpedia.org

In earthquake engineering, vibration control is a set of technical means aimed to mitigate seismic impacts in building and non-building structures. All seismic vibration control devices may be classified as passive, active or hybrid where: When ground seismic waves reach up and start to penetrate a base of a building, their energy flow density, due to reflections, reduces dramatically: usually, up to 90%. However, the remaining portions of the incident waves during a major earthquake still bear a huge devastating potential.

AttributesValues
rdfs:label
  • Seismic vibration control (en)
  • Виброконтроль (ru)
rdfs:comment
  • In earthquake engineering, vibration control is a set of technical means aimed to mitigate seismic impacts in building and non-building structures. All seismic vibration control devices may be classified as passive, active or hybrid where: When ground seismic waves reach up and start to penetrate a base of a building, their energy flow density, due to reflections, reduces dramatically: usually, up to 90%. However, the remaining portions of the incident waves during a major earthquake still bear a huge devastating potential. (en)
  • Виброконтроль (vibration control) является системой устройств для уменьшения сейсмической нагрузки на здания и сооружения. Все эти устройства можно классифицировать как пассивные, активные и гибридные: (ru)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/LRBtest.jpg
  • http://commons.wikimedia.org/wiki/Special:FilePath/SFCityHall.png
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
sameAs
dbp:wikiPageUsesTemplate
thumbnail
has abstract
  • In earthquake engineering, vibration control is a set of technical means aimed to mitigate seismic impacts in building and non-building structures. All seismic vibration control devices may be classified as passive, active or hybrid where: * passive control devices have no feedback capability between them, structural elements and the ground; * active control devices incorporate real-time recording instrumentation on the ground integrated with earthquake input processing equipment and actuators within the structure; * hybrid control devices have combined features of active and passive control systems. When ground seismic waves reach up and start to penetrate a base of a building, their energy flow density, due to reflections, reduces dramatically: usually, up to 90%. However, the remaining portions of the incident waves during a major earthquake still bear a huge devastating potential. After the seismic waves enter a superstructure, there is a number of ways to control them in order to soothe their damaging effect and improve the building's seismic performance, for instance: * to dissipate the wave energy inside a superstructure with properly engineered dampers; * to disperse the wave energy between a wider range of frequencies; * to absorb the resonant portions of the whole wave frequencies band with the help of so-called mass dampers. Devices of the last kind, abbreviated correspondingly as TMD for the tuned (passive), as AMD for the active, and as HMD for the hybrid mass dampers, have been studied and installed in high-rise buildings, predominantly in Japan, for a quarter of a century. However, there is quite another approach: partial suppression of the seismic energy flow into the superstructure known as seismic or base isolation which has been implemented in a number of historical buildings all over the world and remains in the focus of earthquake engineering research for years. For this, some pads are inserted into all major load-carrying elements in the base of the building which should substantially decouple a superstructure from its substructure resting on a shaking ground. It also requires creating a rigidity diaphragm and a moat around the building, as well as making provisions against overturning and P-delta effect. In refineries or plants snubbers are often used for vibration control. Snubbers come in two different variations: hydraulic snubber and a mechanical snubber. * Hydraulic snubbers are used on piping systems when restrained thermal movement is allowed. * Mechanical snubbers operate on the standards of restricting acceleration of any pipe movements to a threshold of 0.2 g's, which is the maximum acceleration that the snubber will permit the piping to see. (en)
  • Виброконтроль (vibration control) является системой устройств для уменьшения сейсмической нагрузки на здания и сооружения. Все эти устройства можно классифицировать как пассивные, активные и гибридные: * устройства пассивного контроля не имеют обратной связи между ними, конструктивными элементами здания и грунтом; * устройства активного контроля включают в себя аппаратуру, записывающую колебания грунта в режиме реального времени и интегрированную, через систему преобразователей, с силовыми приводами и конструктивными элементами здания; * устройства гибридного контроля имеют признаки обеих вышеназванных категорий. * Вибродиагностика является самым точным и информативным методом для определения технического состояния машин и агрегатов. Анализ вибрационного сигнала позволит выявить самые разнообразнейшие дефекты. Расцентровка валов, дисбаланс ротора, трещины в раме и фундаменте, дефекты подшипниковых узлов, кавитация, дефекты обмоток статора, все это может стать причиной нестабильной работы и преждевременного выхода из строя оборудования. Весомым плюсом является то, что диагностика проводится без разборки и остановки агрегата. (ru)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 52 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software