A barostat is a device used to maintain constant pressure in a closed chamber. Its main principle is providing constant pressures in a balloon by means of a pneumatic pump. Barostats are frequently used in neurogastroenterology research, where they are used for measuring gut wall tension or sensory thresholds in the gut. Barostat-balloon systems have been used anywhere in the gut, including the esophagus, stomach, small bowel, colon, and the rectum ampulla.

AttributesValues
rdf:type
rdfs:label
  • Barostat (de)
  • Barostat (en)
rdfs:comment
  • Barostat leitet sich von altgriechisch βάρος báros „Schwere, Gewicht“ und στατός statos = „stehend“ ab, steht also für ein Gerät (oder in Computersimulationen eine Routine) zur Herstellung eines konstanten Drucks. In der neurogastroenterologischen Forschung bezeichnet ein Barostat eine pneumatische Pumpe zum Bereitstellen konstanter Drücke in einem Ballon. Ein Barostat wird benutzt, um Compliance und Tonus der Darmwand zu messen oder um sensorische Schwellen zu bestimmen. (de)
  • A barostat is a device used to maintain constant pressure in a closed chamber. Its main principle is providing constant pressures in a balloon by means of a pneumatic pump. Barostats are frequently used in neurogastroenterology research, where they are used for measuring gut wall tension or sensory thresholds in the gut. Barostat-balloon systems have been used anywhere in the gut, including the esophagus, stomach, small bowel, colon, and the rectum ampulla. (en)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/Barostat_Balloon_rectal.jpg
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
sameAs
dbp:wikiPageUsesTemplate
thumbnail
has abstract
  • A barostat is a device used to maintain constant pressure in a closed chamber. Its main principle is providing constant pressures in a balloon by means of a pneumatic pump. Barostats are frequently used in neurogastroenterology research, where they are used for measuring gut wall tension or sensory thresholds in the gut. A specially designed instrument is needed in neurogastroenterology research since the gut wall has an outstanding capacity to expand and contract spontaneously and by reflex. When this occurs, a balloon placed anywhere in the gut has to be inflated or deflated very rapidly in order to maintain a constant pressure in this balloon. Barostat-balloon systems have been used anywhere in the gut, including the esophagus, stomach, small bowel, colon, and the rectum ampulla. Computer-driven barostats have widely been used to assess sensation and pain thresholds in the gut. Assessment of pain thresholds in the ampulla recti has been proposed as diagnostic measure in irritable bowel syndrome. A typical method for measuring thresholds is the single random staircase or tracking procedure. This is a blend of two paradigms widely used in psychophysical research: ascending stimuli (prone to perception bias) and random stimuli. The latter is regarded as unethical since pain thresholds vary over a wide range in the gut, and therefore stimuli with random intensity can hurt very much. In a tracking procedure, ascending stimuli are used until the threshold is reached. Then the tracking phase begins. If the subject rates a stimulus to be above the threshold, the next stimulus will be chosen in a random process to be a 'stair' higher than the last one or of the same intensity. If, however, the subject rates the stimulus to be under the threshold, a less intense or similar stimulus will follow. Therefore, each stimulus is unpredictable in this phase. An extremely accurate high pressure barostat is also used as a pressure regulator in competition specification precharged pneumatic air rifles and pistols. (en)
  • Barostat leitet sich von altgriechisch βάρος báros „Schwere, Gewicht“ und στατός statos = „stehend“ ab, steht also für ein Gerät (oder in Computersimulationen eine Routine) zur Herstellung eines konstanten Drucks. In der neurogastroenterologischen Forschung bezeichnet ein Barostat eine pneumatische Pumpe zum Bereitstellen konstanter Drücke in einem Ballon. Ein Barostat wird benutzt, um Compliance und Tonus der Darmwand zu messen oder um sensorische Schwellen zu bestimmen. Eine speziell konstruierte Kolbenpumpe wird benötigt, weil die Darmwand sich – spontan und reflexartig – außerordentlich ausdehnen und kontrahieren kann. Ein Ballon, der irgendwo im Darm platziert ist, muss dann schnell aufgeblasen oder es muss Luft abgelassen werden, damit ein konstanter Druck aufrechterhalten werden kann. Barostat-Ballon-Systeme sind überall im Verdauungstrakt benutzt worden, unter anderem in Speiseröhre, Magen, Duodenum, Dickdarm und Rektum. Computergesteuerte Barostate werden häufig verwendet, um Wahrnehmungs- und Schmerzschwellen im Darm zu bestimmen. Schmerzschwellenbestimmung in der Ampulla recti ist als diagnostischer Test für das Reizdarmsyndrom vorgeschlagen worden. Eine typische Methode ist die sogenannte single random staircase- oder tracking-Prozedur. Das ist eine Kombination aus zwei Paradigmen, die in der Psychophysik verwendet werden: aufsteigende Stimuli (die zur Verzerrung tendieren) und zufällige Stimuli. Zufällige Stimuli werden als unethisch angesehen, da Schmerzschwellen bei unterschiedlichen Menschen sehr verschieden sind und daher zufällige Stimuli im Einzelfall sehr wehtun können. In einer tracking-Prozedur werden aufsteigende Stimuli verwendet, bis die Schwelle erstmals erreicht ist. Dann beginnt die tracking-Phase. Wenn der Proband den Stimulus höher als die Schwelle bewertet, dann ist der nächste Stimulus zufällig entweder weniger oder gleich intensiv ausgewählt. Wird der Stimulus dagegen geringer als die Schwelle bewertet, dann ist der nächste Stimulus genauso intensiv oder stärker. Dadurch sind die Stimulusintensitäten nicht vorhersagbar. (de)
gold:hypernym
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software