Electric cell-substrate impedance sensing or ECIS (a trademark of Applied BioPhysics Inc.) refers to a non-invasive biophysical approach to monitor living animal cells in vitro, i.e. within a well-defined laboratory environment.

AttributesValues
rdf:type
rdfs:label
  • Electric Cell-Substrate Impedance Sensing (de)
  • Electric cell-substrate impedance sensing (en)
rdfs:comment
  • Electric Cell-Substrate Impedance Sensing oder kurz ECIS bezeichnet eine sehr breit einsetzbare wissenschaftliche Methode zur Untersuchung lebender tierischer Zellen in vitro, d. h. außerhalb eines lebenden Organismus in einer kontrollierbaren Laborumgebung. (de)
  • Electric cell-substrate impedance sensing or ECIS (a trademark of Applied BioPhysics Inc.) refers to a non-invasive biophysical approach to monitor living animal cells in vitro, i.e. within a well-defined laboratory environment. (en)
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
sameAs
dbp:wikiPageUsesTemplate
has abstract
  • Electric Cell-Substrate Impedance Sensing oder kurz ECIS bezeichnet eine sehr breit einsetzbare wissenschaftliche Methode zur Untersuchung lebender tierischer Zellen in vitro, d. h. außerhalb eines lebenden Organismus in einer kontrollierbaren Laborumgebung. Das Verfahren basiert darauf, die Zellen auf einer flachen Goldfilm-Elektrode aufwachsen zu lassen, die sich auf dem Boden einer Kulturschale (z. B. Petrischale) befindet. Der Wechselstromwiderstand (Impedanz) der zellbedeckten Elektrode wird bei einer oder bei mehreren Frequenzen als Funktion der Zeit gemessen. Da die Zellen sich aufgrund der isolierenden Eigenschaften ihrer Plasmamembran wie dielektrische Partikel verhalten, wird mit zunehmendem Bewuchs der Elektrode die Impedanz zunehmen, bis sich eine kontinuierliche Zellschicht gebildet hat. In kontinuierlichen Zellschichten wird die gemessene Impedanz der zellbedeckten Elektrode maßgeblich durch die Zellform bestimmt. Ändert sich die Zellform infolge eines externen Stimulus, so ändern sich die Stromwege um und durch die Zelle, so dass die gemessene Impedanz sich entsprechend verändert. Durch zeitaufgelöste Impedanzmessung können somit Zellform-Änderungen zeitaufgelöst und in submikroskopischer Auflösung verfolgt und für bioanalytische Zwecke genutzt werden. Da die dreidimensionale Form tierischer Zellen mit hoher Sensitivität auf Veränderungen im Stoffwechsel oder eine chemische, biologische oder physikalische Beeinflussung reagiert, wird das ECIS-Verfahren in einer Vielzahl von Anwendungen in zellbiologisch ausgerichteten biomedizinischen Labors eingesetzt. Es kann zum Wirkstoff- und Cytotoxizitätsscreening genutzt werden oder um die Adhäsion tierischer Zellen an den Untergrund zu untersuchen. (de)
  • Electric cell-substrate impedance sensing or ECIS (a trademark of Applied BioPhysics Inc.) refers to a non-invasive biophysical approach to monitor living animal cells in vitro, i.e. within a well-defined laboratory environment. In ECIS the cells are grown on the surface of small and planar gold-film electrodes, which are deposited on the bottom of a cell culture dish (Petri dish). The AC impedance of the cell-covered electrode is then measured at one or several frequencies as a function of time. Due to the insulating properties of their membranes the cells behave like dielectric particles so that the impedance increases with increasing coverage of the electrode until a confluent (i.e. continuous) layer of cells is established. In confluent cell layers the measured impedance is mainly determined by the three-dimensional shape of the cells. If cell shape changes occur, the current pathways through and around the cell bodies change as well, leading to a corresponding increase or decrease of impedance. Thus, by recording time-resolved impedance measurements, cell shape changes can be followed in real time with sub-microscopic resolution and can be used for bioanalytic purposes. As the shape of animal cells responds very sensitively to alterations in metabolism as well as chemical, biological or physical stimuli, the ECIS technique is applied in various experimental settings in cell biological research laboratories. It can be used as a sensor in cytotoxicity studies, drug development or as a non-invasive means to follow cell adhesion to in vitro surfaces. Equipments based on the ECIS technique are also dedicated to monitor the chemokinetic activity of adherent cells spread on the electrode surface (micromotion) as well as their chemotactic activities in ECIS-based wound healing assays. (en)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage disambiguates of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 56 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software