Oxidation induction time or OIT is a standardized test performed in a DSC which measures the level of thermal stabilization of the material tested. The time between melting and the onset of decomposition in isothermal conditions is measured. The atmosphere is nitrogen up to melting and then oxygen. The typical temperature is 190-220 °C. This test is routine when assessing the quality of organic materials or polymers, such as polyethylene pipes.

AttributesValues
rdf:type
rdfs:label
  • Oxidative-induction time (en)
rdfs:comment
  • Oxidation induction time or OIT is a standardized test performed in a DSC which measures the level of thermal stabilization of the material tested. The time between melting and the onset of decomposition in isothermal conditions is measured. The atmosphere is nitrogen up to melting and then oxygen. The typical temperature is 190-220 °C. This test is routine when assessing the quality of organic materials or polymers, such as polyethylene pipes. (en)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/Oit.png
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
thumbnail
has abstract
  • Oxidation induction time or OIT is a standardized test performed in a DSC which measures the level of thermal stabilization of the material tested. The time between melting and the onset of decomposition in isothermal conditions is measured. The atmosphere is nitrogen up to melting and then oxygen. The typical temperature is 190-220 °C. Oxidation-induction time can be known with the use of Differential Scanning Calorimetry measurements, which is done with the sample body and a substance that will be heated in a constant rate in an atmosphere of inert gas. Once the specified temperature is attained, its atmosphere will be replaced by an air atmosphere of the said rate or an oxygen atmosphere. The specimen will be then held at a constant temperature up to the indication of oxidative reaction by exothermal deviation of DSC heat flow curve. Time interval in the middle of the start of the air flow and the beginning of the oxidation reaction is called the isothermal OIT. The said method was also mentioned and discussed on several various technical standards like DIN EN ISO 11357-6. This test is routine when assessing the quality of organic materials or polymers, such as polyethylene pipes. (en)
gold:hypernym
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is Wikipage disambiguates of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software