quantium Medical Cardiac Output (qCO) uses impedance cardiography in a simple, continuous, and non-invasive way to estimate the cardiac output (CO) and other hemodynamic parameters such as the stroke volume (SV) and cardiac index (CI). The CO estimated by the qCO monitor is referred to as the "qCO". The impedance plethysmography allows determining changes in volume of the body tissues based on the measurement of the electric impedance at the body surface.

AttributesValues
rdfs:label
  • Quantium Medical Cardiac Output (en)
rdfs:comment
  • quantium Medical Cardiac Output (qCO) uses impedance cardiography in a simple, continuous, and non-invasive way to estimate the cardiac output (CO) and other hemodynamic parameters such as the stroke volume (SV) and cardiac index (CI). The CO estimated by the qCO monitor is referred to as the "qCO". The impedance plethysmography allows determining changes in volume of the body tissues based on the measurement of the electric impedance at the body surface. (en)
name
  • quantium Medical Cardiac Output (en)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/Frank_Starling’s_curve.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/CO_Incresing.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/FFT_qCO.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/Passive_Leg_Raising_test.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/QCO_location.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/Sepsis_monitor.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/Stroke_volume_decresing.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/qCO_waves.png
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
sameAs
dbp:wikiPageUsesTemplate
thumbnail
align
  • center (en)
caption
  • Figure 2: Time relationship between the ECG, dZ and dZ/dt waveforms. The more characteristic points of the dZ/dt waveform are identified as B, which is the opening moment to the aortic valve . The C is the maximum blood flow in the left ventricle . The X reveals the closing of aortic valve and the LVET is the time interval between the opening and closure of the aortic valve, i.e., the interval between the points B and X. (en)
  • Figure 1: Recommended location of the electrodes. For using the qCO it is only necessary to place the electrodes, connect it to a PC via USB and run the software. (en)
direction
  • horizontal (en)
image
  • QCO_location.png (en)
  • qCO_waves.png (en)
purpose
  • estimate cardiac output (en)
width
has abstract
  • quantium Medical Cardiac Output (qCO) uses impedance cardiography in a simple, continuous, and non-invasive way to estimate the cardiac output (CO) and other hemodynamic parameters such as the stroke volume (SV) and cardiac index (CI). The CO estimated by the qCO monitor is referred to as the "qCO". The impedance plethysmography allows determining changes in volume of the body tissues based on the measurement of the electric impedance at the body surface. The assessment of Cardiac Output (CO) is important because it reveals the main cardiac function: the supply of blood to tissues. CO reflects the hemodynamic flow and hence the transport of oxygen; its clinical applications by non-invasive continuous hemodynamic monitoring are especially useful for some medical specialties like anaesthesiology, emergency care and cardiology, for example to prevent hypoperfusion and to guide fluid administration. Several authors advocate the high reliability and good correlation of cardiography impedance compared to others techniques more established. Nevertheless, some detractors complain about the sensitivity of the technique to artefacts such as the electromyography or breathing movements. (en)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software