About: Resonance ionization     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : owl:Thing, within Data Space : dbpedia.demo.openlinksw.com associated with source document(s)
QRcode icon
http://dbpedia.demo.openlinksw.com/c/2mM1LAtvRH

Resonance ionization is a process in optical physics used to excite a specific atom (or molecule) beyond its ionization potential to form an ion using a beam of photons irradiated from a pulsed laser light. In resonance ionization, the absorption or emission properties of the emitted photons are not considered, rather only the resulting excited ions are mass-selected, detected and measured. Depending on the laser light source used, one electron can be removed from each atom so that resonance ionization produces an efficient selectivity in two ways: elemental selectivity in ionization and isotopic selectivity in measurement.

AttributesValues
rdfs:label
  • Resonance ionization (en)
rdfs:comment
  • Resonance ionization is a process in optical physics used to excite a specific atom (or molecule) beyond its ionization potential to form an ion using a beam of photons irradiated from a pulsed laser light. In resonance ionization, the absorption or emission properties of the emitted photons are not considered, rather only the resulting excited ions are mass-selected, detected and measured. Depending on the laser light source used, one electron can be removed from each atom so that resonance ionization produces an efficient selectivity in two ways: elemental selectivity in ionization and isotopic selectivity in measurement. (en)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/GS_Hurst.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/Resonance_Ionization_Picture_new_2.png
  • http://commons.wikimedia.org/wiki/Special:FilePath/U.S._Department_of_Energy_-_Science_-_389_036_002_(10158953803).jpg
dct:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
thumbnail
number
title
  • Method of analyzing for a component in a sample (en)
  • Resonance ionization for analytical spectroscopy (en)
has abstract
  • Resonance ionization is a process in optical physics used to excite a specific atom (or molecule) beyond its ionization potential to form an ion using a beam of photons irradiated from a pulsed laser light. In resonance ionization, the absorption or emission properties of the emitted photons are not considered, rather only the resulting excited ions are mass-selected, detected and measured. Depending on the laser light source used, one electron can be removed from each atom so that resonance ionization produces an efficient selectivity in two ways: elemental selectivity in ionization and isotopic selectivity in measurement. During resonance ionization, an ion gun creates a cloud of atoms and molecules from a gas-phase sample surface and a tunable laser is used to fire a beam of photons at the cloud of particles emanating from the sample (analyte). An initial photon from this beam is absorbed by one of the sample atoms, exciting one of the atom's electrons to an intermediate excited state. A second photon then ionizes the same atom from the intermediate state such that its high energy level causes it to be ejected from its orbital; the result is a packet of positively charged ions which are then delivered to a mass analyzer. Resonance ionization contrasts with resonance-enhanced multiphoton ionization (REMPI) in that the latter is neither selective nor efficient since resonances are seldom used to prevent interference. Also, resonance ionization is used for an atomic (elemental) analyte, whereas REMPI is used for a molecular analyte. The analytical technique on which the process of resonance ionization is based is termed resonance ionization mass spectrometry (RIMS). RIMS is derived from the original method, resonance ionization spectroscopy (RIS), which was initially being used to detect single atoms with better time resolution. RIMS has proved useful in the investigation of radioactive isotopes (such as for studying rare fleeting isotopes produced in high-energy collisions), trace analysis (such as for discovering impurities in highly pure materials), atomic spectroscopy (such as for detecting low-content materials in biological samples), and for applications in which high levels of sensitivity and elemental selectivity are desired. (en)
Asignee
  • The United States of America as represented by the United States Energy Research and Development Administration (en)
inventor
  • George S. Hurst, Marvin G. Payne, Edward B. Wagner (en)
  • Hurst, G. Samuel, James E. Parks, James E. & Schmitt, Harold W (en)
issue-date
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git147 as of Sep 06 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3331 as of Sep 2 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 51 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software