Thermowells are cylindrical fittings used to protect temperature sensors installed in industrial processes. A thermowell consists of a tube closed at one end and mounted in the process stream. A temperature sensor such as a thermometer, thermocouple, or resistance temperature detector is inserted in the open end of the tube, which is usually in the open air outside the process piping or vessel and any thermal insulation. Thermodynamically, the process fluid transfers heat to the thermowell wall, which in turn transfers heat to the sensor. Since more mass is present with a sensor-well assembly than with a probe directly immersed into the process, the sensor's response to process temperature changes is slowed by the addition of the well. If the sensor fails, it can be easily replaced without

AttributesValues
rdfs:label
  • Thermometerschutzrohr (de)
  • Thermowell (en)
rdfs:comment
  • Thermometerschutzrohre oder Tauchhülsen sind wichtige Komponenten von Temperaturmessstellen. Sie dichten einen Prozess zur Umgebung hin ab und halten aggressive Medien sowie hohe Drücke und Fließgeschwindigkeiten vom eigentlichen Temperaturfühler fern. Erst dadurch ermöglichen sie eine Temperaturmessung in hochbelasteten Prozessen oder in aggressiven oder toxischen Medien. (de)
  • Thermowells are cylindrical fittings used to protect temperature sensors installed in industrial processes. A thermowell consists of a tube closed at one end and mounted in the process stream. A temperature sensor such as a thermometer, thermocouple, or resistance temperature detector is inserted in the open end of the tube, which is usually in the open air outside the process piping or vessel and any thermal insulation. Thermodynamically, the process fluid transfers heat to the thermowell wall, which in turn transfers heat to the sensor. Since more mass is present with a sensor-well assembly than with a probe directly immersed into the process, the sensor's response to process temperature changes is slowed by the addition of the well. If the sensor fails, it can be easily replaced without (en)
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
Link from a Wikipage to an external page
sameAs
dbp:wikiPageUsesTemplate
has abstract
  • Thermometerschutzrohre oder Tauchhülsen sind wichtige Komponenten von Temperaturmessstellen. Sie dichten einen Prozess zur Umgebung hin ab und halten aggressive Medien sowie hohe Drücke und Fließgeschwindigkeiten vom eigentlichen Temperaturfühler fern. Erst dadurch ermöglichen sie eine Temperaturmessung in hochbelasteten Prozessen oder in aggressiven oder toxischen Medien. (de)
  • Thermowells are cylindrical fittings used to protect temperature sensors installed in industrial processes. A thermowell consists of a tube closed at one end and mounted in the process stream. A temperature sensor such as a thermometer, thermocouple, or resistance temperature detector is inserted in the open end of the tube, which is usually in the open air outside the process piping or vessel and any thermal insulation. Thermodynamically, the process fluid transfers heat to the thermowell wall, which in turn transfers heat to the sensor. Since more mass is present with a sensor-well assembly than with a probe directly immersed into the process, the sensor's response to process temperature changes is slowed by the addition of the well. If the sensor fails, it can be easily replaced without draining the vessel or piping. Since the mass of the thermowell must be heated to the process temperature, and since the walls of the thermowell conduct heat out of the process, sensor accuracy and responsiveness is reduced by the addition of a thermowell. Traditionally the thermowell length has been based in the degree of insertion relative to pipe wall diameter. This tradition is misplaced as it can expose the thermowell to the risk of flow-induced vibration and fatigue failure. When measurement error calculations are carried out for the installation, for insulated piping or near ambient fluid temperatures, excluding thermal radiation effects, conduction error is less than one percent as long as the tip is exposed to flow, even in flanged mounted installations. The response time of the installed sensor is largely governed by the fluid velocity and considerably greater than the response time of the sensor itself. This is the result of the thermal mass of the thermowell tip, and the heat transfer coefficient between the thermowell and the fluid. Arguments for longer designs are based on traditional notions but rarely justified. Long thermowells may be used in low velocity services or in cases where historical experience justified their use. In modern high strength piping and elevated fluid velocities, each installation must be carefully examined especially in cases where acoustic resonances in the process are involved. A representative thermowell is machined from drilled bar stock to ensure a proper sensor fit (ex: an 0.260-inch bore matching an 0.250-inch sensor). A thermowell is typically mounted into the process stream by way of a threaded, welded, sanitary cap, or flanged process connection. The temperature sensor such as a thermometer, thermocouple, or resistance temperature detector is inserted in the open end of the thermowell and typically spring-loaded to ensure that the outside tip of the temperature sensor is in metal to metal contact with the inside tip of the thermowell. The use of welded sections for long designs is discouraged due to corrosion and fatigue risks. (en)
gold:hypernym
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 59 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software