A common-path interferometer is a class of interferometers in which the reference beam and sample beams travel along the same path. Examples include the Sagnac interferometer, Zernike phase-contrast interferometer, and the point diffraction interferometer. A common-path interferometer is generally more robust to environmental vibrations than a "double-path interferometer" such as the Michelson interferometer or the Mach–Zehnder interferometer. Although travelling along the same path, the reference and sample beams may travel along opposite directions, or they may travel along the same direction but with the same or different polarization.
Attributes | Values |
---|
rdf:type
| |
rdfs:label
| - Interferómetro de trayecto común (es)
- Common-path interferometer (en)
|
rdfs:comment
| - A common-path interferometer is a class of interferometers in which the reference beam and sample beams travel along the same path. Examples include the Sagnac interferometer, Zernike phase-contrast interferometer, and the point diffraction interferometer. A common-path interferometer is generally more robust to environmental vibrations than a "double-path interferometer" such as the Michelson interferometer or the Mach–Zehnder interferometer. Although travelling along the same path, the reference and sample beams may travel along opposite directions, or they may travel along the same direction but with the same or different polarization. (en)
- Un interferómetro de trayecto común es una clase de interferómetro en el que el rayo de referencia y el rayo analizado recorren el mismo camino. Los ejemplos incluyen el interferómetro de Sagnac, el interferómetro de punto de difracción, y el interferómetro de Zernike de contraste de fase. Un interferómetro de trayecto común generalmente es más resistente a vibraciones externas que un "interferómetro de camino doble" como el interferómetro de Michelson o el interferómetro de Mach-Zehnder. Aunque viajen a lo largo del mismo camino, el rayo de referencia y el de muestra pueden hacerlo en sentidos opuestos, o pueden viajar a lo largo de la misma dirección pero con la misma o distinta polarización. (es)
|
foaf:depiction
| |
dcterms:subject
| |
Wikipage page ID
| |
Wikipage revision ID
| |
Link from a Wikipage to another Wikipage
| |
sameAs
| |
dbp:wikiPageUsesTemplate
| |
thumbnail
| |
has abstract
| - A common-path interferometer is a class of interferometers in which the reference beam and sample beams travel along the same path. Examples include the Sagnac interferometer, Zernike phase-contrast interferometer, and the point diffraction interferometer. A common-path interferometer is generally more robust to environmental vibrations than a "double-path interferometer" such as the Michelson interferometer or the Mach–Zehnder interferometer. Although travelling along the same path, the reference and sample beams may travel along opposite directions, or they may travel along the same direction but with the same or different polarization. Double-path interferometers are highly sensitive to phase shifts or length changes between the reference and sample arms. Because of this, double-path interferometers have found wide use in science and industry for the measurement of small displacements, refractive-index changes, surface irregularities and the like. There are applications, however, in which sensitivity to relative displacement or refractive-index differences between reference and sample paths is not desirable; alternatively, one may be interested in the measurement of some other property. (en)
- Un interferómetro de trayecto común es una clase de interferómetro en el que el rayo de referencia y el rayo analizado recorren el mismo camino. Los ejemplos incluyen el interferómetro de Sagnac, el interferómetro de punto de difracción, y el interferómetro de Zernike de contraste de fase. Un interferómetro de trayecto común generalmente es más resistente a vibraciones externas que un "interferómetro de camino doble" como el interferómetro de Michelson o el interferómetro de Mach-Zehnder. Aunque viajen a lo largo del mismo camino, el rayo de referencia y el de muestra pueden hacerlo en sentidos opuestos, o pueden viajar a lo largo de la misma dirección pero con la misma o distinta polarización. Los interferómetros de camino doble son altamente sensibles a cambios de fase o a cambios de longitud del recorrido entre el rayo de referencia y el rayo de muestra. Debido a esto, los interferómetros de camino doble han encontrado un amplio uso en ciencia e industria para la medida de desplazamientos pequeños, cambios de índice de refracción, irregularidades de superficie y otras propiedades similares. (es)
|