A forced circulation boiler is a boiler where a pump is used to circulate water inside the boiler. This differs from a natural circulation boiler which relies on current density to circulate water inside the boiler. In some forced circulation boilers, the water is circulated twenty times the rate of evaporation.

AttributesValues
rdf:type
rdfs:label
  • Zwanglaufkessel (de)
  • Forced circulation boiler (en)
rdfs:comment
  • A forced circulation boiler is a boiler where a pump is used to circulate water inside the boiler. This differs from a natural circulation boiler which relies on current density to circulate water inside the boiler. In some forced circulation boilers, the water is circulated twenty times the rate of evaporation. (en)
  • Der Zwanglaufkessel findet seine Anwendung im konventionell befeuerten Dampfkraftwerk zur Erzeugung von Wasserdampf. Die Bauart unterscheidet sich vom Naturumlaufkessel durch ihre Arbeitsweise. Beim Naturumlaufkessel zirkuliert das Speisewasser aufgrund seines Dichteunterschiedes, beim Zwanglaufkessel fördert die Speisepumpe das zu verdampfende Wasser durch die Rohrbündel des als Wärmeübertrager ausgeführten Dampferzeugers. Dadurch ist eine kleinere Bauform erreichbar als bei einem Naturumlaufkessel. Des Weiteren ist eine gleichmäßigere Regulierung der Dampferzeugung möglich, da nicht nur durch die Temperatur der Verbrennung, sondern auch über den Wasserdurchsatz gesteuert werden kann. (de)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/NCFC_Comparison.jpg
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
sameAs
dbp:wikiPageUsesTemplate
thumbnail
has abstract
  • Der Zwanglaufkessel findet seine Anwendung im konventionell befeuerten Dampfkraftwerk zur Erzeugung von Wasserdampf. Die Bauart unterscheidet sich vom Naturumlaufkessel durch ihre Arbeitsweise. Beim Naturumlaufkessel zirkuliert das Speisewasser aufgrund seines Dichteunterschiedes, beim Zwanglaufkessel fördert die Speisepumpe das zu verdampfende Wasser durch die Rohrbündel des als Wärmeübertrager ausgeführten Dampferzeugers. Dadurch ist eine kleinere Bauform erreichbar als bei einem Naturumlaufkessel. Des Weiteren ist eine gleichmäßigere Regulierung der Dampferzeugung möglich, da nicht nur durch die Temperatur der Verbrennung, sondern auch über den Wasserdurchsatz gesteuert werden kann. Die Zwanglaufkessel können in zwei große Arten unterschieden werden, den Zwangumlaufkessel (z. B. LaMont-Kessel) und den Zwangdurchlaufkessel (z. B. Benson- oder Sulzerkessel). Die Arten der Zwanglaufkessel unterscheiden sich im Wesentlichen durch die Art der Rohrwicklung beziehungsweise Rohranordnung. Ein Zwangumlaufkessel besitzt in der Regel eine Dampftrommel für das umlaufende Wasser. Die Zwangdurchlaufkessel sind trommellos, da das Wasser am Ende eines Verdampferrohres vollständig verdampft ist. (de)
  • A forced circulation boiler is a boiler where a pump is used to circulate water inside the boiler. This differs from a natural circulation boiler which relies on current density to circulate water inside the boiler. In some forced circulation boilers, the water is circulated twenty times the rate of evaporation. In water tube boilers, the way the water is recirculated inside the boiler before becoming steam can be described as either natural circulation or forced circulation. In a water tube boiler, the water is recirculated inside until the vapor pressure of the water overcomes the vapor pressure inside the stream drum and becomes saturated steam. The forced circulation boiler begins the same as a natural circulation boiler, at the feed water pump. Water is introduced into the steam drum and is circulated around the boiler, leaving only as steam. What makes the forced circulation boiler different is its use of a secondary pump that circulates water through the boiler. The secondary pump takes the feed water going to the boiler and raises the pressure of the water going in. In a natural circulation boilers, the circulation of water is dependent on the differential pressures caused by the change of density in the water as it is heated. That is to say that as the water is heated and starts turning to steam, the density decreases sending the hottest water and steam to the top of the furnace tubes. In contrast to the natural circulation boiler, the forced circulation boiler uses a water circulation pump to force that flow instead of waiting for the differential to form. Because of this, the generation tubes of a forced circulation boiler are able to be oriented in whatever way is required by space constraints. Water is taken from the drum and forced through the steel tubes. In this way it is able to produce steam much faster than that of a natural circulation boiler (en)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 59 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software