An RX meter is used to measure the separate resistive and reactive components of reactive parallel Z network. The two variable frequency oscillators track each other at frequencies 100 kHz apart. The output of a 0.5-250 MHz oscillator, F1, is fed into a bridge. When the impedance network to be measured is connected one arm across the bridge, the equivalent parallel resistance and reactance (capacitive or inductive) unbalances the bridge and the resulting voltage is fed to the mixer. The output of the 0.6-250.1 MHz oscillator F2, tracking 100 kHz above F1, is also fed to the mixer. This results in a 100 kHz difference frequency proportional in level to the bridge unbalance. The difference frequency signal is amplified by a filter amplifier combination and is applied to a null meter. When th

AttributesValues
rdf:type
rdfs:label
  • RX meter (en)
rdfs:comment
  • An RX meter is used to measure the separate resistive and reactive components of reactive parallel Z network. The two variable frequency oscillators track each other at frequencies 100 kHz apart. The output of a 0.5-250 MHz oscillator, F1, is fed into a bridge. When the impedance network to be measured is connected one arm across the bridge, the equivalent parallel resistance and reactance (capacitive or inductive) unbalances the bridge and the resulting voltage is fed to the mixer. The output of the 0.6-250.1 MHz oscillator F2, tracking 100 kHz above F1, is also fed to the mixer. This results in a 100 kHz difference frequency proportional in level to the bridge unbalance. The difference frequency signal is amplified by a filter amplifier combination and is applied to a null meter. When th (en)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/RX_meter.jpg
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
sameAs
dbp:wikiPageUsesTemplate
thumbnail
has abstract
  • An RX meter is used to measure the separate resistive and reactive components of reactive parallel Z network. The two variable frequency oscillators track each other at frequencies 100 kHz apart. The output of a 0.5-250 MHz oscillator, F1, is fed into a bridge. When the impedance network to be measured is connected one arm across the bridge, the equivalent parallel resistance and reactance (capacitive or inductive) unbalances the bridge and the resulting voltage is fed to the mixer. The output of the 0.6-250.1 MHz oscillator F2, tracking 100 kHz above F1, is also fed to the mixer. This results in a 100 kHz difference frequency proportional in level to the bridge unbalance. The difference frequency signal is amplified by a filter amplifier combination and is applied to a null meter. When the bridge resistive and reactive controls are nulled, their respective dials accurately indicate the parallel impedance components of the network under test. The best-known RX Meter was the RX250-A, developed in the early 1950s by Boonton Radio Corporation. After acquiring BRC, Hewlett-Packard continued to sell versions of the meter (both the original and the improved 250B) into the late 1960s. (en)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software