The stacking factor (also lamination factor or space factor) is a measure used in electrical transformer design and some other electrical machines. It is the ratio of the effective cross-sectional area of the transformer core to the physical cross-sectional area of the transformer core. The two are different because of the way cores are constructed. The stacking factor is used when calculating the magnetic flux density within the core. Because the flux is confined within a smaller area in a laminated core, the flux density is higher than it would be in a homogeneous core.

AttributesValues
rdfs:label
  • معامل الحزم (ar)
  • Stacking factor (en)
rdfs:comment
  • يستخدم معامل الحزم (أو معامل التراص Stacking factor) في عملية تصميم المحولات الكهربائية . وبسبب أن المحولات تتكون من صفائح معدنية، غالبا من تكون من الحديد، ويتم إجراء عمليه التصفيح ( وهي عملية الريط بين عنصرين أو أكثر بالغراء والضغط ) . وهدف هذة العملية هو التخلص من التيارات الدوامية المتكون في القلب الحديدي، مع الحفاظ على قيمة المجال بأكبر قدر ممكن . وعملية التصفيح لا تستخدم سبائك حديدية مغناطيسية، لذلك يجب إخد قيمتها في الاعتبار عند حساب كثافة الفيض. ويعطي معامل الحزم رقم تقريبي لنسبة تأثير صفائح القلب الحديدي عند حساب كثافة الفيض . (ar)
  • The stacking factor (also lamination factor or space factor) is a measure used in electrical transformer design and some other electrical machines. It is the ratio of the effective cross-sectional area of the transformer core to the physical cross-sectional area of the transformer core. The two are different because of the way cores are constructed. The stacking factor is used when calculating the magnetic flux density within the core. Because the flux is confined within a smaller area in a laminated core, the flux density is higher than it would be in a homogeneous core. (en)
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
sameAs
dbp:wikiPageUsesTemplate
has abstract
  • يستخدم معامل الحزم (أو معامل التراص Stacking factor) في عملية تصميم المحولات الكهربائية . وبسبب أن المحولات تتكون من صفائح معدنية، غالبا من تكون من الحديد، ويتم إجراء عمليه التصفيح ( وهي عملية الريط بين عنصرين أو أكثر بالغراء والضغط ) . وهدف هذة العملية هو التخلص من التيارات الدوامية المتكون في القلب الحديدي، مع الحفاظ على قيمة المجال بأكبر قدر ممكن . وعملية التصفيح لا تستخدم سبائك حديدية مغناطيسية، لذلك يجب إخد قيمتها في الاعتبار عند حساب كثافة الفيض. ويعطي معامل الحزم رقم تقريبي لنسبة تأثير صفائح القلب الحديدي عند حساب كثافة الفيض . (ar)
  • The stacking factor (also lamination factor or space factor) is a measure used in electrical transformer design and some other electrical machines. It is the ratio of the effective cross-sectional area of the transformer core to the physical cross-sectional area of the transformer core. The two are different because of the way cores are constructed. Transformer cores are usually made up of thin metal sheets stacked in layers. The layers are laminated with varnish or other insulating material. The purpose is to reduce eddy currents in the core, while keeping a high magnetic flux. Since the insulator is non-ferro-magnetic, little, if any, magnetic flux is contained within it. It is mainly in the metal sheets. The insulation takes up a finite space, so the effective area the flux occupies is less than the physical area of the core. The stacking factor is used when calculating the magnetic flux density within the core. Because the flux is confined within a smaller area in a laminated core, the flux density is higher than it would be in a homogeneous core. Laminated cores always have a stacking factor less than unity; a stacking factor of unity implies no laminate at all. Stacking factors are typically 0.95 or higher for transformer cores and machine stators. However, cores made from amorphous metal have a stacking factor of around 0.8, compared to 0.96 for silicon steel. A related concept in transformer design is window space factor. This is defined as the ratio of the area occupied by the copper windings to the area of the space they pass through (the "window"). The higher the operational voltage of the transformer, the smaller this ratio needs to be in order to provide more space for insulation. (en)
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 59 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software