This HTML5 document contains 113 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dbpedia-dehttp://de.dbpedia.org/resource/
n20http://dbpedia.org/resource/Wikt:
dctermshttp://purl.org/dc/terms/
yago-reshttp://yago-knowledge.org/resource/
dbohttp://dbpedia.org/ontology/
foafhttp://xmlns.com/foaf/0.1/
n16https://global.dbpedia.org/id/
yagohttp://dbpedia.org/class/yago/
dbthttp://dbpedia.org/resource/Template:
rdfshttp://www.w3.org/2000/01/rdf-schema#
freebasehttp://rdf.freebase.com/ns/
dbpedia-plhttp://pl.dbpedia.org/resource/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
owlhttp://www.w3.org/2002/07/owl#
dbpedia-ithttp://it.dbpedia.org/resource/
wikipedia-enhttp://en.wikipedia.org/wiki/
dbchttp://dbpedia.org/resource/Category:
provhttp://www.w3.org/ns/prov#
dbphttp://dbpedia.org/property/
xsdhhttp://www.w3.org/2001/XMLSchema#
wikidatahttp://www.wikidata.org/entity/
goldhttp://purl.org/linguistics/gold/
dbrhttp://dbpedia.org/resource/

Statements

Subject Item
dbr:Volatile_corrosion_inhibitor
rdf:type
yago:Matter100020827 yago:Substance100020090 dbo:Drug yago:Inhibitor114724436 yago:PhysicalEntity100001930 yago:WikicatCorrosionInhibitors
rdfs:label
Volatile corrosion inhibitor Inibitore volatile di corrosione Volatile Corrosion Inhibitor Metoda VCI
rdfs:comment
Metoda VCI – metoda zabezpieczenia metali przed korozją za pomocą lotnych inhibitorów korozji (VCI, ang. Vapor/Volatile Corrosion Inhibitor). Metoda VCI polega na powolnym odparowywaniu inhibitora z papieru lub folii, w którą zapakowany jest metalowy przedmiot i zapobieganiu korodowaniu jego powierzchni. Inhibitor tworzy na powierzchni warstwę o grubości od 4 do 5 cząsteczek, a następnie pary inhibitora wypełniają wolną przestrzeń pomiędzy ośrodkiem emitujący inhibitor a chronioną powierzchnią. Cząsteczki inhibitora są emitowane z powierzchni papieru lub folii aż do jego wyczerpania. Tak zabezpieczona część może być przechowywana nawet do 24 miesięcy. Ein Volatile Corrosion Inhibitor (VCI) (flüchtiger Korrosions-Verhinderer) wird als temporäres Korrosionsschutzmittel für metallische Werkstoffe eingesetzt. Wirksam ist die langsam verdunstende oder sublimierende Substanz in der Dampfphase oder nach der Kondensation auf dem Werkstoff. Gebräuchliche Inhibitoren sind * für Kupfer Benzotriazol bzw. Tolyltriazol (schwächere Wirkung auch auf Zink) * für Eisen sowie A volatile corrosion inhibitor (VCI) is a material that protects metals from corrosion. V.VCI is also called Vacuum VCI meaning they have special properties of performance in vacuum as well as corrosion protection properties. Corrosion inhibitors are chemical compounds that can decrease the corrosion rate of a material, typically a metal or an alloy. NACE International Standard TM0208 defines volatile corrosion inhibitor (VCI) as a chemical substance that acts to reduce corrosion by a combination of volatilization from a VCI material, vapor transport in the atmosphere of an enclosed environment, and condensation onto surface in the space, including absorption, dissolution, and hydrophobic effects on metal surfaces, where the rate of corrosion of metal surfaces is thereby inhibited. They al Un materiale inibitore volatile di corrosione (o VCI, dall'inglese Volatile Corrosion Inhibitor) è un materiale che riduce la velocità di corrosione di un oggetto metallico quando questo è racchiuso in spazi ristretti (ovvero in imballaggi).
dcterms:subject
dbc:Corrosion_prevention dbc:Coatings dbc:Corrosion_inhibitors dbc:Packaging dbc:Corrosion
dbo:wikiPageID
38529942
dbo:wikiPageRevisionID
1092443918
dbo:wikiPageWikiLink
dbr:Storage_tank dbr:Sour_crude_oil dbr:Leak_detection dbc:Corrosion_prevention dbr:Pigging dbr:Cosmoline dbr:Thermal_insulation dbr:PH dbr:Wet_gas dbr:Vapor_pressure dbr:Volatilisation dbr:Absorption_(chemistry) dbr:Aldehyde dbr:Corrosion_inhibitor dbr:Biodegradability dbr:Ferrous dbr:Metal dbr:Petroleum dbr:Condensation dbr:Chemical_compound dbr:Perforation dbr:Acetylene dbr:Engine dbr:Benzotriazole dbr:Vapor dbr:Patent dbr:Non-ferrous_metal dbr:United_States_Armed_Forces dbr:Room_temperature dbr:Junction_box dbr:Formulation dbr:Polyethylene dbr:Boiler dbr:Molecular_evolution dbr:Stratified_flows dbr:Dissolution_(chemistry) dbr:Chemical_transport_reaction dbr:Cleaning_agent dbr:Strong_base dbr:Rust dbr:Sulfur_dioxide dbr:Flange dbr:Diffusion dbr:Hydrostatic_test dbr:Corrosion_engineering dbc:Coatings dbr:Aqueous_solution dbr:Coating dbr:Oil dbr:NACE_International dbr:Chemical_substance dbr:Corrosion dbr:Shell_Oil_Company dbr:Steel n20:dispensers dbr:Desiccant dbr:Hydrophobe dbr:Alloy dbr:Packaging dbr:Adsorption dbr:Heat_exchanger dbc:Corrosion_inhibitors dbr:Electrical_enclosure dbr:Dissociation_(chemistry) dbr:Pascal_(unit) dbr:Heavy_metals dbr:Azole dbr:Annulus_(mathematics) dbc:Packaging dbr:Water_treatment dbc:Corrosion dbr:Valve dbr:Ion dbr:Hydraulics dbr:Copper
owl:sameAs
dbpedia-it:Inibitore_volatile_di_corrosione dbpedia-pl:Metoda_VCI wikidata:Q2530663 freebase:m.0r4r5bq n16:2Nxxs dbpedia-de:Volatile_Corrosion_Inhibitor yago-res:Volatile_corrosion_inhibitor
dbp:wikiPageUsesTemplate
dbt:Citation_style dbt:Reflist
dbo:abstract
A volatile corrosion inhibitor (VCI) is a material that protects metals from corrosion. V.VCI is also called Vacuum VCI meaning they have special properties of performance in vacuum as well as corrosion protection properties. Corrosion inhibitors are chemical compounds that can decrease the corrosion rate of a material, typically a metal or an alloy. NACE International Standard TM0208 defines volatile corrosion inhibitor (VCI) as a chemical substance that acts to reduce corrosion by a combination of volatilization from a VCI material, vapor transport in the atmosphere of an enclosed environment, and condensation onto surface in the space, including absorption, dissolution, and hydrophobic effects on metal surfaces, where the rate of corrosion of metal surfaces is thereby inhibited. They also called vapor-phase inhibitors, vapor-phase corrosion inhibitors, and vapor-transported corrosion inhibitors. VCIs come in various formulations that are dependent on the type of system they will be used in; for example, films, oils, coatings, cleaners, etc. There are also variety of formulations that provide protection in ferrous, nonferrous, or multi-metal applications. Other variables include the amount of vapor phase compared to contact phase inhibitors (1). Because they are volatile at ambient temperature, VCI compounds can reach inaccessible crevices in metallic structures (2). Metoda VCI – metoda zabezpieczenia metali przed korozją za pomocą lotnych inhibitorów korozji (VCI, ang. Vapor/Volatile Corrosion Inhibitor). Metoda VCI polega na powolnym odparowywaniu inhibitora z papieru lub folii, w którą zapakowany jest metalowy przedmiot i zapobieganiu korodowaniu jego powierzchni. Inhibitor tworzy na powierzchni warstwę o grubości od 4 do 5 cząsteczek, a następnie pary inhibitora wypełniają wolną przestrzeń pomiędzy ośrodkiem emitujący inhibitor a chronioną powierzchnią. Cząsteczki inhibitora są emitowane z powierzchni papieru lub folii aż do jego wyczerpania. Tak zabezpieczona część może być przechowywana nawet do 24 miesięcy. Metoda ta rozwiązuje wiele problemów ochrony przed korozją tam, gdzie nie jest możliwe zastosowanie tradycyjnych sposobów. Wykorzystywana jest w przemyśle metalowym, hutniczym, lotniczym, wojskowym oraz w elektronice. Zaletą tej metody jest to, że powierzchnia poddawana ochronie jest czysta, sucha i gotowa do użycia w każdym momencie, bez konieczności dodatkowych operacji usuwania środka. Ein Volatile Corrosion Inhibitor (VCI) (flüchtiger Korrosions-Verhinderer) wird als temporäres Korrosionsschutzmittel für metallische Werkstoffe eingesetzt. Wirksam ist die langsam verdunstende oder sublimierende Substanz in der Dampfphase oder nach der Kondensation auf dem Werkstoff. VCI-Materialien entfalten ihre Wirkung an der Metalloberfläche, an der sie adsorbiert werden und eine Schutzschicht gegen die Einwirkungen von Sauerstoff und/oder Wasser ausbilden. Sie zeichnen sich durch einen hohen Dampfdruck bei relativ niedrigen Temperaturen aus. Es handelt sich dabei z. B. um Salze (Amine, Nitrite), die in Papier oder Trägerfolien eingebracht werden, aus denen sie dann allmählich ausgasen. Wird das zu schützende Werkstück von dieser Verpackung umschlossen, stellt sich eine mit dem Inhibitor gesättigte Atmosphäre ein. Nach dem Entpacken des Werkstückes verflüchtigt sich der Inhibitor ohne Rückstände. Darin liegt auch der wesentliche Vorteil gegenüber Schutzschichten aus Ölen oder Wachsen, die aufwändig entfernt werden müssen. Gebräuchliche Inhibitoren sind * für Kupfer Benzotriazol bzw. Tolyltriazol (schwächere Wirkung auch auf Zink) * für Eisen sowie Un materiale inibitore volatile di corrosione (o VCI, dall'inglese Volatile Corrosion Inhibitor) è un materiale che riduce la velocità di corrosione di un oggetto metallico quando questo è racchiuso in spazi ristretti (ovvero in imballaggi).
gold:hypernym
dbr:Inhibitor
prov:wasDerivedFrom
wikipedia-en:Volatile_corrosion_inhibitor?oldid=1092443918&ns=0
dbo:wikiPageLength
19477
foaf:isPrimaryTopicOf
wikipedia-en:Volatile_corrosion_inhibitor