Mass-analyzed ion kinetic-energy spectrometry (MIKES) is a mass spectrometry technique by which mass spectra are obtained from a sector instrument that incorporates at least one magnetic sector plus one electric sector in reverse geometry (the beam first enters the magnetic sector). The accelerating voltage V, and the magnetic field B, are set to select the precursor ions of a particular m/z. The precursor ions then dissociate or react in an electric field-free region between the two sectors. The ratio of the kinetic energy to charge of the product ions are analyzed by scanning the electric sector field E. The width of the product ion spectrum peaks is related to the kinetic energy release distribution for the dissociation process.

AttributesValues
rdf:type
rdfs:label
  • Spettrometria MIKES (it)
  • Mass-analyzed ion-kinetic-energy spectrometry (en)
rdfs:comment
  • Mass-analyzed ion kinetic-energy spectrometry (MIKES) is a mass spectrometry technique by which mass spectra are obtained from a sector instrument that incorporates at least one magnetic sector plus one electric sector in reverse geometry (the beam first enters the magnetic sector). The accelerating voltage V, and the magnetic field B, are set to select the precursor ions of a particular m/z. The precursor ions then dissociate or react in an electric field-free region between the two sectors. The ratio of the kinetic energy to charge of the product ions are analyzed by scanning the electric sector field E. The width of the product ion spectrum peaks is related to the kinetic energy release distribution for the dissociation process. (en)
  • La spettrometria MIKES è una tecnica di spettrometria di massa oggi abbandonata; MIKES è l'acronimo dell'inglese mass-analyzed ion kinetic energy spectrometry. In questa tecnica si monta l'analizzatore di massa a doppio fuoco in geometria inversa (prima il settore magnetico e poi il settore elettrostatico). Il voltaggio di accelerazione V, e il campo magnetico B, sono impostati per selezionare uno ione precursore a un determinato m/z. Lo ione precursore si frammenta in una zona priva di campo elettrico tra i due settori e viene analizzato il rapporto energia cinetica/carica degli ioni prodotto. La larghezza dei picchi degli ioni prodotto è in relazione con la distribuzione di energia cinetica liberata durante il processo di dissociazione. (it)
foaf:depiction
  • http://commons.wikimedia.org/wiki/Special:FilePath/Jeol_5sector.jpg
  • http://commons.wikimedia.org/wiki/Special:FilePath/MIKES_schematic.jpg
dcterms:subject
Wikipage page ID
Wikipage revision ID
Link from a Wikipage to another Wikipage
sameAs
dbp:wikiPageUsesTemplate
thumbnail
has abstract
  • Mass-analyzed ion kinetic-energy spectrometry (MIKES) is a mass spectrometry technique by which mass spectra are obtained from a sector instrument that incorporates at least one magnetic sector plus one electric sector in reverse geometry (the beam first enters the magnetic sector). The accelerating voltage V, and the magnetic field B, are set to select the precursor ions of a particular m/z. The precursor ions then dissociate or react in an electric field-free region between the two sectors. The ratio of the kinetic energy to charge of the product ions are analyzed by scanning the electric sector field E. The width of the product ion spectrum peaks is related to the kinetic energy release distribution for the dissociation process. (en)
  • La spettrometria MIKES è una tecnica di spettrometria di massa oggi abbandonata; MIKES è l'acronimo dell'inglese mass-analyzed ion kinetic energy spectrometry. In questa tecnica si monta l'analizzatore di massa a doppio fuoco in geometria inversa (prima il settore magnetico e poi il settore elettrostatico). Il voltaggio di accelerazione V, e il campo magnetico B, sono impostati per selezionare uno ione precursore a un determinato m/z. Lo ione precursore si frammenta in una zona priva di campo elettrico tra i due settori e viene analizzato il rapporto energia cinetica/carica degli ioni prodotto. La larghezza dei picchi degli ioni prodotto è in relazione con la distribuzione di energia cinetica liberata durante il processo di dissociazione. (it)
gold:hypernym
prov:wasDerivedFrom
page length (characters) of wiki page
foaf:isPrimaryTopicOf
is Link from a Wikipage to another Wikipage of
is Wikipage redirect of
is Wikipage disambiguates of
is foaf:primaryTopic of
Faceted Search & Find service v1.17_git139 as of Feb 29 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 08.03.3330 as of Mar 19 2024, on Linux (x86_64-generic-linux-glibc212), Single-Server Edition (378 GB total memory, 60 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software